Please see attached scope for proper formatting. Electrical Engineering Scope for Taft Mini Golf Project Overview New 18-hole mini-golf facility located at 421 Kern Street, Taft, CA. 6,250 sq ft vacant lot. Single 64 sq ft ADA bathroom, parking area, and trash enclosure located along the alley. Taft Mini Golf operated as a temporary business last year. What was done for that will be similar to the permanent project. You can find pictures of the temporary project at [login to view URL] and [login to view URL] Electrical System Overview New grid-tied 150A service drop from PG&E. There is no current power on the lot. Electric system is a 120/240V, 1-phase, 3-wire setup. Site loads include ADA path lighting with 90-minute battery backup, parking area lighting, and two outdoor receptacles in the maintenance area. Bathroom loads include an interior light with 90-minute battery backup, exterior door light with 90-minute battery backup, mechanical exhaust fan, and a 2.5-gallon mini-tank water heater for hand washing. The foundation for the ADA bathroom is gravel with earth anchors. Electrical system grounding may need to be done by grounding rods. Scope of Services Review provided preliminary site layouts, single-line diagrams, and fixture schedules and make any changes required. Review and provide responses to the city for the following comments (see attached city comments), also make necessary plan changes: Section - Title sheet Item #2b [see page 2] (Provide reference codes) - Electrical codes only Section - Means of egress Item #15j [see page 4] (1 foot-candle illumination) - Electrical Engineer to respond Section - Means of egress Item #15m [see page 4] (1 foot-candle illumination) - Electrical Engineer to respond Section - Energy code Item #25 [see page 5] (Title-24 energy calculations are missing) - Electrical Engineer to respond. Section - Energy code Item #26a [see page 5] (All mandatory compliance forms must be completed) - Electrical Engineer to respond. Section - Energy code Item #26b [see page 5] (Compliance forms must be signed by responsible person) - Electrical Engineer to respond Section - Energy code Item #26c [see page 5] (Forms must be permanently printed on the plans.) - Electrical Engineer to respond Complete, sign and print on the plans the title-24 Energy Calculations Complete, sign and print on the plans all non-residential energy compliance forms as applicable. 2025 CEnC (California Energy Code) Provide signed and stamped calculations for site lighting and bathroom. As noted in the city comments. Verify the preliminary load calculations of 5.2 kVA connected load and 5.6 kVA calculated demand load. Perform official voltage drop and conduit fill calculations to finalize the 150A feeder wire size. Confirm California Electrical Code (CEC) and Title 24 compliance for the specified exterior/interior lighting and sensors. Provide detail and plan location for grounding rods if required. Provide one of the following: final CAD drafting with plans as PDF prints and original CAD for owners use, OR provide redlines allowing the owner to draft and finalize the electrical sheets. Sign and stamp the final electrical plans for City of Taft permit approval. Additional Services (Billed Separately / As Needed) Plan Check Revisions: Respond to City of Taft plan check comments and provide a stamped second submittal if required. Construction Support: Provide construction administration services at an agreed-upon hourly rate if an on-site inspector requires field changes or additional documentation. Provided Reference Documents CAD files will be provided to the Electrical Engineer if required. C-01: Site Plan, Table of Contents and General Notes. E-101: Electrical Site Plan. E-501: Single Line Diagram and Legend. E-511: Electrical Fixture Schedule and Notes. First submittal to city (Note: The first submittal targeted a standalone/off the shelf solar generator setup. Based on the comments received we no longer think this a viable approach, as noted above the project will use a grid tied system. City comments on first submittal (Note: see scope above for specific comment numbers that require electrical engineering assistance). Exclusions Engineer estimating is not required. Bid support and review are not required. Required Deliverables Final stamped Electrical Engineering Plan Set and any required electrical calculations or memos/reports (Owner is not aware of any memos or reports required). Digital version of all documents prepared in native format and PDF, if Electrical Engineer selected to provide drafting instead of readlines. Timeline and Compensation Draft Review: Target date for initial draft review is 2 weeks from Notice to Proceed (NTP). Final Delivery: Target date for final stamped deliverables is 1 week after receiving all comments and instructions from the owner. Base Fee: Agreed-upon lump sum fee for baseline engineering and stamping services. Hourly Rate: Defined hourly rate for any "Additional Services" triggered during plan check or construction.
Project ID: 40668542
9 proposals
Remote project
Active 1 day ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
9 freelancers are bidding on average $520 USD for this job

Hello sir I have 11 years of experience as a Senior Electrical Power Systems Engineer leading an electrical design team across commercial site power distribution, Title 24 energy calculations, photometric egress lighting analysis, and municipal plan check approvals. We specialize in preparing permit-ready electrical plan sets compliant with the California Electrical Code (CEC) and California Energy Code. Engineering Scope & Plan Check Strategy for Taft Mini Golf Grid-Tied 120/240V Service & Panelboard Design: Reviewing and finalizing the single-line diagram (SLD) for a new 150A, 1-phase, 3-wire utility service drop from PG&E. Verifying main disconnect sizing, service entrance conductors, and branch distribution for site lighting, maintenance receptacles, and ADA bathroom loads (mini-tank water heater, exhaust fan, lighting). Load Calculations & Voltage Drop Sizing: Re-evaluating preliminary load calculations (5.2 kVA connected / 5.6 kVA demand) and performing official feeder voltage drop and conduit fill calculations to confirm 150A conductor sizing and breaker protection under CEC standards. Grounding & Bonding System: Designing a CEC-compliant Grounding Electrode System (GES) utilizing dual driven copper grounding rods and grounding electrode conductors (GEC) tailored for the gravel-foundation ADA bathroom structure. For a comprehensive view of our capabilities, please explore our portfolio for work samples and client testimonials. Regards, Eslam
$450 USD in 4 days
5.3
5.3

Hi, I can provide the electrical engineering review and permit-ready documentation for the Taft Mini Golf project, including the new 150A, 120/240V single-phase PG&E service, site/restroom lighting, receptacles, water heater, exhaust fan, grounding, and associated calculations. My scope would include reviewing E-101, E-501, E-511 and the city plan-check comments; verifying the 5.2 kVA connected / 5.6 kVA demand loads; completing voltage-drop and conduit-fill calculations; checking feeder sizing, grounding electrodes, emergency lighting, and CEC/Title 24 compliance. I can also address the required 1-foot-candle egress illumination, 90-minute emergency lighting, Title 24 energy calculations/forms, lighting controls, and provide clear responses to the City of Taft comments. Final deliverables can include updated CAD/PDF electrical sheets, calculations, and plan-check response documentation. I’m experienced with electrical distribution, load calculations, lighting, grounding, NEC/CEC compliance, CAD documentation, and permit-plan review. I can target the initial review within 2 weeks and final stamped deliverables after owner comments, consistent with your requested schedule. Regards.
$500 USD in 7 days
3.3
3.3

Hello, With over five decades of construction experience, including 42 years as a licensed contractor in California, my firm and I bring unmatched acumen to electrical engineering projects. We have an intricate understanding of the construction landscape, having masterminded various projects from conception to completion. This strong background enables us to establish electrical systems that are not just code-compliant, but also cost-effective, on Taft Mini Golf’s empty lot. My expertise is rooted in construction consulting, architectural drafting support, and project management - a perfect mosaic needed for your mini-golf facility. I can provide site layouts and plans that genuinely capture the true essence of your project. I understand how much adherence to scope matters; hence, I will ensure every detail aligns with your initial plans. To guarantee you receive the best possible service and satisfy Taft City's requirements, I am willing to perform official voltage drop and conduit fill calculations to finalize the 150A feeder wire size. Moreover, I will verify all fixtures meet California Electrical Code (CEC) and Title 24 compliance. Trust me to sign and stamp the final electrical plan for safekeeping before City of Taft permit approval so that your project faces no administrative hindrances in its execution. Let me take charge of your electrical project for both accuracy and efficacy in results. Thank you for considering my services! Thanks!
$555 USD in 5 days
0.0
0.0

Hello, I can assist with the electrical CAD and documentation for your Taft Mini Golf project. I have experience with AutoCAD technical drawings, electrical layouts, and organized documentation. I can deliver accurate, clean, and professional drawings according to your requirements, with attention to detail and timely delivery. I’m ready to start immediately. Let’s discuss the project details and get started. Best regards, Vishakha
$389 USD in 3 days
0.0
0.0

Beverly Hills, United States
Payment method verified
Member since Aug 24, 2026
$25-30 USD
$15-25 USD / hour
₹37500-75000 INR
₹20000-75000 INR
₹400-750 INR / hour
$50-150 USD
$10-30 USD
$250-750 AUD
₹37500-75000 INR
$25-50 USD / hour
$30-250 USD
$30-250 USD
$25-50 AUD / hour
$15-25 USD / hour
$10-15 USD
$30-250 AUD
$80-90 USD
$30-250 USD
$10 USD
$1500-3000 USD