I need an engineer who already feels at home with the IEC60870-5-104 telemetry stack to build and fine-tune a Windows-based server that will stream real-time data from our power-plant generators. The job is centred on live monitoring, so low latency, reliable packet handling and solid time-stamping are critical. You will install, configure and secure the server, connect it to the existing generator IEDs, and prove that the data flows continuously to the SCADA front-end without drops or mismatches. Please include parameter tuning (t0, t1, t2, k, w, etc.), TLS or VPN set-up if you normally deploy it, and clear operator documentation. Acceptance criteria • Generator measurements visible on the supervisor console with ≤1 s delay • All test points pass IEC conformance diagnostics and survive a 48-hour soak • Handover package: config files, step-by-step restart guide and a short troubleshooting checklist If this sounds routine to you, let’s get started.
Project ID: 40561593
9 proposals
Remote project
Active 6 days ago
Set your budget and timeframe
Get paid for your work
Outline your proposal
It's free to sign up and bid on jobs
9 freelancers are bidding on average ₹47,972 INR for this job

With over a decade of experience as a Network, Cybersecurity, and System Engineer, I am confident in my ability to successfully complete your project. I have a deep understanding of network administration, security, and Windows Server that will prove invaluable in setting up the IEC60870-5-104 telemetry stack on your Windows-based server. My proficiency with vendors like Cisco, Fortinet and Microsoft will ensure that your system aligns with industry best practices. The acceptance criteria for this job are crystal clear – visibility of generator measurements on the supervisor console within 1 second delay, conformance diagnostics adherence, and a comprehensive handover package. I guarantee to meet these expectations whilst providing any necessary operator documentation you may require. In addition to my technical expertise, I pride myself on being available around the clock to address any issues that may arise during your project. My quick responses and high rate of project delivery will give you the confidence that this undertaking's completion will be both efficient and effective. Given the unique nature of this project and its need for intimacy with the IEC60870-5-104 telemetry stack, I am well-positioned to provide you with impeccable service. Let's transform your power-plant monitoring system together!
₹50,000 INR in 7 days
7.0
7.0

Drawing from my expertise in Product Visualization, Software Development, and DevOps, I believe I have the combination of skills essential for your telemetry project. Although cognitive dissonance can be unsettling, rest easy knowing I am all too familiar with the IEC60870-5-104 stack and understand how important low-latency, reliable packet handling, and solid timestamping are to live monitoring operations like yours. My track record demonstrates my knack for installing, configuring and securing servers with great precision to ensure uninterrupted flow of data to the SCADA front-end. My troubleshooting abilities and meticulous approach towards documentation make me especially qualified for this project. Whether it's parameter tuning or the establishment of secure connections like TLS or VPN – which I frequently deploy – ensuring smooth operations takes precedence in my work ethic. Likewise, my thorough understanding of generator IEDs and data conformance diagnostics will guarantee exceptional results that meet your acceptance criteria in terms of visibility, latency, and system upkeep even during extended periods like a 48-hour soak.
₹56,250 INR in 3 days
3.9
3.9

Hi, I can set up and configure your Windows-based IEC60870-5-104 server for real-time power-plant generator monitoring with reliable packet handling, low latency, secure connectivity, and clean SCADA data flow. The best solution is to first review your generator IED configuration, network topology, SCADA front-end requirements, point list, addressing, time-stamping method, and IEC104 communication parameters. Then I’ll install and configure the server, tune t0/t1/t2/k/w parameters, validate data mapping, secure the connection using VPN/TLS where suitable, and run stability checks to confirm continuous live data transfer. I’m comfortable with IEC60870-5-104 telemetry, Windows Server setup, SCADA communication, IED connectivity, real-time monitoring, parameter tuning, network troubleshooting, VPN/security configuration, diagnostics, logging, and operator documentation. Deliverables will include: * Windows IEC104 server setup * Generator IED connection configuration * SCADA front-end data validation * IEC104 parameter tuning * Point mapping verification * Latency and packet-drop checks * VPN/TLS security setup if required * 48-hour soak test support * Config files handover * Restart guide and troubleshooting checklist I’ll focus on stable, low-latency data streaming, accurate point mapping, and clear handover documentation so your operators can monitor generator data confidently without recurring communication issues. Best regards Ankit
₹37,500 INR in 7 days
3.5
3.5

Hello Boss, I have experience working with Windows Server, industrial communication, and SCADA-related integrations. I can install, configure, and optimize an IEC 60870-5-104 server, connect it with your generator IEDs, tune protocol parameters (t0, t1, t2, k, w), and ensure reliable low-latency data delivery to your SCADA system. I'll also provide complete documentation, configuration files, a restart guide, and a troubleshooting checklist after successful testing. One question: which SCADA platform and IEC-104 server software are you currently using (e.g., WinCC OA, Geo SCADA, VTScada, Beckhoff, or another solution)? I look forward to working with you, Boss.
₹55,000 INR in 15 days
1.8
1.8

Building and tuning a Windows Server 2022 instance that streams live IEC60870-5-104 telemetry from your generator IEDs to the SCADA supervisor console, with parameter optimisation, TLS/VPN fronting and a clean operator handover package. I stood up an IEC104 master on a Windows host for a power-monitoring use case in my own pipeline, tuned t0/t1/t2/k/w against simulated outages, and ran a multi-day soak where the client side verified packet-level integrity against their front-end. The deliverable that landed cleanly was a single config bundle plus a one-page restart-and-recovery doc. Quick question: are the IEDs reachable via VPN from a workstation I can spin up here, or do I need to remote-in to your SCADA host? That decides whether I deliver a tested-and-validated bundle against a live simulator or a config-only package you run the soak on. Approach: 1. Provision a hardened Windows Server 2022 box (or use the one you expose), open 2404/TCP, install an IEC60870-5-104 master (lib60870 or commercial), and bind it to the supervisor interface. 2. Configure the protocol stack: timing parameters t0/t1/t2/k/w, ASDU addressing, and station/point mapping, plus an explicit cause-of-transmission policy for spontaneous and interrogation responses. 3. Front the master with TLS (mutual) or wrap it in your existing VPN, then run a 48-hour soak against a live IED (or the simulator), capturing latency histograms and any dropped frames. 4. Hand back: config files (server, TLS, firewall), a restart-and-recovery script, and a short operator troubleshooting checklist. Milestones (totalling 100%): 30% on server provisioned, IEC104 master installed and accepting a single IED's spontaneous reports 40% on parameter tuning complete and 48-hour soak passed (≤1 s supervisor delay, no drops) 30% on handover package delivered (config, restart guide, troubleshooting checklist) Happy to start with a 48-hour soak proof on one IED so you can confirm the latency and packet-integrity numbers before the rest of the fleet is wired in.
₹42,500 INR in 12 days
0.0
0.0

With hands-on experience deploying and troubleshooting IEC 60870-5-104 communication systems, I can deliver a secure, reliable Windows-based telemetry server optimized for real-time power plant monitoring. I understand the importance of low latency, accurate time synchronization, and stable communication with generator IEDs. I will configure and fine-tune protocol parameters (t0, t1, t2, k, w), implement secure connectivity using TLS or VPN where required, validate performance through IEC conformance testing, and ensure successful 48-hour soak testing. You'll receive complete configuration files, clear operator documentation, a restart guide, and a practical troubleshooting checklist for smooth long-term operation and maintenance.
₹56,250 INR in 7 days
0.0
0.0

Drawing from my extensive experience in industrial automation, I believe I am highly capable of handling your IEC60870-5-104 Windows Server Setup project. I have successfully completed numerous projects involving real-time data handling from complex systems, including Wastewater and Water Treatment Plant Automation. On these projects, I ensured successful communication between multiple subsystems, wrote detailed system software, and provided reliable monitoring and control techniques. In my previous roles, my work with Siemens TIA Portal program, Simatic Manager program and Siemens WinCC SCADA program will be specifically valuable for the tasks at hand. I have also dealt extensively with Siemens PH & Information Server program which aligns closely with the operator documentation needs you have specified. Additionally, both my knowledge of ABB & Siemens drivers and my usage of Honeywell DCS C200 in iron steel industry is pertinent for the set-up and tuning needed to ensure minimal packet drops or mismatches in your project.
₹56,250 INR in 7 days
0.0
0.0

Chennai, India
Payment method verified
Member since Jul 2, 2025
₹37500-75000 INR
₹50000-100000 INR
₹1500-12500 INR
₹1500-12500 INR
₹12500-37500 INR
$15-25 USD / hour
$250-750 USD
₹600-1500 INR
₹12500-37500 INR
$10-30 CAD
min $50 USD / hour
$30-250 USD
$250-750 NZD
₹150000-250000 INR
₹750-1250 INR / hour
$250-750 USD
$100-500 USD
£20-250 GBP
$30-250 AUD
$250-750 USD
₹12500-37500 INR
€30-250 EUR
$25-50 USD / hour
$10-30 USD
$15-25 USD / hour